Equipment › ANVER Vacuum Components › Vacuum Switches and Sensors › JTZSE digital control switch
The JTZSE and JTZSE-R2 are compact compound pressure gauges with switch outputs, eight operation modes and eight pressure units.
Vacuum system components
Digital vacuum/pressure control switches
Model JTZSE and model JTZSE-R2 digital control switches
Model JTZSE digital control switch for non-corrosive gases
This popular model used for non-corrosive gases [compound and low pressure] is a compact multi-purpose compound pressure gauge, specifically designed to cover negative-to-normal pressure. A rear mount bracket option is available.
Model JTZSE-R2 digital control switch for liquids or gases
This special high corrosion resistant model [compound and absolute pressure] has pressure port attachments made of SUS 316L stainless steel for exact, accurate pressure control to cover a broad range of applications.
Features
Digital vacuum/pressure control switch specifications
Model number | Pressure port | Diaphragm material | Net weight (including 2 m cable) | Accessories |
JTZSE | Aluminum die-casting Rc 1/8 female, 2 places | Silicone, single crystal | 2.928 oz. (83 grams) | Unit seal, seal screw, M5 connecting joint screw |
JTZSE-R2 | Mounting: R 1/4, with M5 female | SUS316L | 5.291 oz. (150 grams) | Unit seal |
Pressure reference: gauge – pressure setting range
Model number | Rated pressure range | kPa | gf/cm² | mmHg | mbar | psi | Breakdown pressure |
JTZSE | -100 to 1000 kPa | -999 to 999 | -999 to 999 | -760 to 760 | n/a | -14.5 to 14.5 | 500 kPa |
JTZSE-R2 | -100 to 100 kPa | -99.9 to 99.9 | -999 to 999 | -760 to 760 | -999 to 999 | -14.5 to 14.5 | 300 kPa |
Switch output
Model number | General specifications | Hysteresis | Repeatability | Response | Short circuit protection |
JTZSE | 2-point output, NPN/PNP transistor open collector, capacity: 30 V DC 100 mA max., residual voltage: 1.2 V or below (at load current of 100 mA) | 0 – 300 digits (adjustable) | +/- 0.2% F. S. +/- 1 digit | 5 ms maximum | Provided |
| JTZSE-R2 |
Output mode setting (detected pressure – pin)
Model number | Output mode | R mode | G mode | V mode | Output voltage Vo |
JTZSE | Pin (H) | +Pr | -Pr | -Pr | Vo(H) |
JTZSE-R2 | Pin (L) | -Pr | O | O | Vo(L) |
Environmental characteristics
Model number | Protection grade | Operating temp. range | Storage temp. range | Operating humidity | Insulation resistance | Dielectric strength | Vibration | Shock |
JTZSE | IP65 (Pressure Gauge Body): Conforming to IEC | 14° to 122°F (-10 to 50°C) | 68° to 158°F (20° to 70°C) | 35 to 85% Relative Humidity | More than 100 M ohm at DC 500 V between wire bundle and pressure port | One minute at AC 500 V between wire bundle and pressure port (leak current: less than 1 mA) | 10-55 Hz, amplitude 0.75 mm, 3 directions, 2 h each | +/-3% F.S. (0 ± 50°C) |
JTZSE-R2 |
General
Model number | Analog output | Display | Negative pressure display | Switch state indication |
JTZSE | Output voltage: 1-5 V (zero point 1 V ± 0.2 V, span 4 V ± 0.2 V) | Full 3 digit LED (Sampling Cycle: 4/second) | Negative Pressure LED is on | Output 1 (green) and output 2 (red) light up when output is on: Thermal Error |
| JTZSE-R2 |
Send photos, weight and dimensions of the load. FullSharp represents ANVER and replies with a configuration and quote within 24 hours.