Equipment › ANVER Vacuum Components › Air Powered Vacuum Pumps › JB Single-Stage Pumps › JEHCSP Vacuum Generator
The JEHCSP Economizer series handles non-porous loads where vacuum loss is unacceptable. A fast acting check valve prevents leakage.
Energy-Saver Vacuum Pumps with Pneumatic Pilot Valve
JEHCSP Economizer Series
Equip your vacuum generator with an air supply control valve and a fast-acting vacuum switch to save energy. The JEHCSP Series uses compressed air only when required to maintain the programmed level. Whenever the vacuum level drops 5% below the preset level, the generator is reactivated. A fast acting check valve that prevents leakage is also included.
The “Economizer” series brings a new level of efficiency to the handling and holding of non-porous materials and objects. Use this system when the loss of vacuum is unacceptable. The JEHCSP is equipped with pneumatic control for explosion-proof operation. The pneumatic switch and mounting plate can be oriented in various positions for specific application needs.
Note: This system requires a separate on/off valve in the circuit to release the load.
| Compressed air: | 50 micron, filtered, non-lubricated |
| Operating temp.: | 0 to 60°C = 32 to 140°F |
| Optimum operating pressure: | 6 bar = 85-90 psi |
| Mechanical life: | 15 million cycles |
| Valve material: | Anodized aluminum, brass nozzle |
| Seals materials: | Nitrile NBR |
| Part Number | Nozzle Size | D in. (mm) | L1 in. (mm) | L2 in. (mm) | H in. (mm) | W in. (mm) | Item Weight oz. (grams) | Air Consumption SCFM (l/min.) | Vacuum Flow SCFM (l/min.) | Vacuum Level in Hg (-mmHg) | |
| JE12HCSP | 12 | 0.77 (20) | 4.41 (112) | 1.40 (35) | 1.89 (48) | 3.71 (94) | 12.275 (348) | 2.1 (59) | 1.9 (54) | 27 (686) | |
| JE15HCSP | 15 | 0.77 (20) | 4.80 (122) | 1.40 (35) | 1.89 (48) | 3.71 (94) | N/A | 3.2 (91) | 2.7 (76) | 27 (686) | |
| JE20HCSP | 20 | 1.25 (32) | 4.22 (107) | 2.97 (75) | 1.93 (49) | 3.71 (94) | N/A | 6.1 (170) | 4.5 (127) | 27 (686) | |
| JE25HCSP | 25 | 1.25 (32) | 4.22 (107) | 2.97 (75) | 1.93 (49) | 3.71 (94) | N/A | 9.2 (260) | 7.1 (201) | 27 (686) | |
| JE JE Series | 12 Nozzle Size 12 15 20 25 | H | CS Control Valve Supply and Check Valve | P Pilot P = Pneumatic |
Send photos, weight and dimensions of the load. FullSharp represents ANVER and replies with a configuration and quote within 24 hours.