ANVER motor starters combine short circuit protection, overload protection and switching in one compact unit, and each now comes with an enclosure.
Electric vacuum pump station accessories
Motor starters and protectors for vacuum pumps
ANVER motor starters are made to the highest quality standards. The motor circuit controller combines the function of:
Short circuit protection
3 phase
Manual starter
ANVER starters can eliminate the need for larger and more expensive fuse blocks and fused disconnects, or circuit breakers.
ANVER starters offer a wide application range, from 0.1 to 25 Full Load Amp (FLA). For group motor applications, ANVER starters have a group installation rating of up to 600V @ 2,000 Amp, one of the highest in the industry.
ANVER starters are also excellent as manual motor starters that employ all of the same motor protection features in one compact unit. ANVER starters are the most compact on the market today.
In the event of a short-circuit, the contacts are opened by non-adjusting tripping elements in times approaching 1/1000 of a second.
Because each ANVER starter is individually calibrated at the factory for the smallest and largest current, very accurate thermal overload protection is also obtained. Each motor starter now comes with an enclosure.
Motor starter specifications:
Horsepower ratings shown in the table below are for reference. The final selection of the manual starter depends on the actual motor full load current and service factor.
ANVER part no. | Amperage range | Phase | Item weight lb (kg) | Maximum HP | |||
Minimum | Maximum | 230V | 460V | 575V | |||
ST-025-040 | 2.50 | 4.00 | Three | N/A | 3/4 | 2 | 3 |
ST-040-063 | 4.00 | 6.29 | Three | 1.66 (0.75) | 1½ | 3 | 5 |
ST-063-100 | 6.30 | 9.99 | Three | N/A | 3 | 5 | 7½ |
ST-100-160 | 10.00 | 15.99 | Three | 1.66 (0.75) | 5 | 10 | 10 |
Appropriate motor starters for ANVER vacuum pumps:
ANVER pump no. | HP | Recommended starter no. | Voltage | Amps | Port size | Hose in. (mm) |
VB4HF | 4.6 HP | ST-100-160 | 208-230 | 12.6 | 2″ NPT | 2 (50.8) |
ST-063-100 | 460 | 7.3 | ||||
ST-040-063 | 575 | 5 | ||||
VB7HV | 4.8 HP | ST-100-160 | 208-230 | 10.3 | 1-1/4″NPT | 2 (50.8) |
ST-063-100 | 460 | 5.0 | ||||
ST-025-040 | 575 | 3.9 | ||||
VB8HF | 8.5 HP | ST-200-250 | 208-230 | 24 | 2″ NPT | 2 (50.8) |
ST-100-160 | 460 | 12 | ||||
ST-100-160 | 575 | 8.5 | ||||
VB9HV | 7.5 HP | ST-160-200 | 208-230 | 16.4 | 1-1/4″NPT | 2 (50.8) |
ST-063-100 | 460 | 9.5 | ||||
ST-040-063 | 575 | 5.4 |
Electrical transformers for vacuum generators:
Model number | Unit weight | Used with generator | Incoming primary voltage | Outgoing secondary voltage | Wattage | A Depth | B Width | C Height | D Top holes | E Bottom holes | F Distance from top to bottom holes | Item weight lb (kg) |
VLT-01 | 30 lbs | VPE1 VPF-57 | 240V, 480V 60Hz | 120V 60Hz | 1.5KVA | 5.2 in. 132 mm | 5.5 in. 140 mm | 10.3 in. 262 mm | 1.4 in. 36 mm | 2.4 in. 61 mm | 11.6 in. 295 mm | N/A |
VLT-03 | 38 lbs | VPE3 | 240V, 480V 60Hz | 120V 60Hz | 2KVA | 4.5 in. 114 mm | 4.8 in. 122 mm | 11.8 in. 300 mm | 1.4 in. 36 mm | 2.1 in. 53 mm | 13.0 in. 330 mm | N/A |
VLT-06 | 30 lbs | VPE1 VPF-57 | 600V 60Hz | 120V 60Hz | 1.5KVA | 5.2 in. 132 mm | 5.5 in. 140 mm | 10.3 in. 262 mm | 1.4 in. 36 mm | 2.4 in. 61 mm | 11.6 in. 295 mm | N/A |
VLT-14 | 38 lbs | VPE1 VPF-57 VPE3 | 190V, 200V 208V, 380V 400V, 416V 50/60Hz | 120V 50/60Hz | 2KVA | 5.2 in. 132 mm | 5.5 in. 140 mm | 13 in. 330 mm | 1.4 in. 36 mm | 2.1 in. 53 mm | 13.5 in. 343 mm | 3.81 (1.73) |
Note: All ANVER electrical components, controls and wiring follow international standards: UL, CSA, NFPA, NEC. It is the user’s responsibility to comply with all additional local electrical codes as they pertain to the installation.
Important: The ASME B30.20 regulations, which are the American standard (ASME website) state this about “(i) Power disconnects.
(1) Hoisting Equipment using an externally powered vacuum lifter shall have a separate vacuum lifter circuit switch of the enclosed type with provision for locking, flagging, or tagging in the open (off) position. The vacuum lifter disconnect switch shall be connected on the line side (power supply side) of the hoisting equipment disconnect switch. (2) Disconnects are not required on externally powered vacuum lifters operating a 120 VAC single phase power source.”
Send photos, weight and dimensions of the load. FullSharp represents ANVER and replies with a configuration and quote within 24 hours.