ANVER Regenerative Vacuum Stations and Vacuum Pumps, VB Series

ANVER direct-drive regenerative vacuum pumps are the quiet, virtually maintenance-free vacuum source for vacuum lifting systems. This page lists dimensions, electrical data, explosion-proof models, sound enclosures and mufflers.

Vacuum Pumps and Vacuum Generators: Regenerative Vacuum Stations and Vacuum Pumps

Standard regenerative direct-drive vacuum pumps and vacuum stations with internal filter and relief valve

Manufacturer PDF

Note: Vacuum Stations include a muffler and fittings

ANVER VB41HF-FR-S regenerative vacuum station

ANVER offers select models of high efficiency vacuum pumps specially designed for ANVER, and used as part of its vacuum lifting systems. These revolutionary regenerative pumps offer a compact, reliable source of quiet, vibration-free vacuum. ANVER’s quality vacuum pumps are made from tough, high-strength materials for long life, and are lightweight and virtually maintenance free. Their highly efficient, state-of-the-art design has rendered the older designs of conventional side-channel blowers obsolete. Powered by high quality motors, they are more energy efficient, require less horsepower to operate than competitive models, and are offered in a variety of sizes to match your vacuum lifting requirements. NOTE: Optional vacuum or pressure relief valves are also recommended.

Optional sound enclosures, specifically designed for this pump model, are available and further reduce the noise level by 5–7dB.

Performance chart of ANVER VB41HF-FR-S vacuum pump

Dimensional drawing of ANVER VB41HF-FR vacuum pump

Notes: *Refer to the pump specification label for actual ratings. Data listed in the table below is subject to change. Before using the pump, confirm that your operating requirements are compatible with the data on the pump specification label.

Specifications
Model No.VB41HF-FR-S
A [in. (mm)]27 (686)
B [in. (mm)]18.4 (468)
C [in. (mm)]17.9 (455)
D [in. (mm)]12.2 (310)
E [in. (mm)]12.2 (310)
F [in. (mm)]24.25 (616)
Pump Weight [lbs (kg)]119 (54)
Power [HP (Kw)]6.4 (4.8)
Flow at 50/60Hz [SCFM (m3/hr)]114 (193) / 138 (234)
Maximum Vacuum [in. Hg (mbar)]12.9 (436)
Running Temp [°F (°C)]104 (40)
Sound [dB]71 / 73
Amps @ 230/460 VAC* at 60Hz16.5/8.25
Amps @ 208 VAC* at 50Hz17.1
Muffler Part NumberMU-VB2
Spare / Replacement Filter Elements for VB41HF-FR-S
Product PhotoPart NumberDescription
ANVER FLTE41-PA paper filter elementFLTE41-PA

Filter Element Inlet, for VB41HF (Paper)

  • 99% Filtration Efficiency at 2 µm
ANVER FLTE41-PO polyester filter elementFLTE41-PO

Filter Element Inlet, for VB41HF (Polyester)

  • 99% Filtration Efficiency at 5 µm

Information about atmospheric pressure

Standard regenerative direct-drive vacuum pumps and vacuum stations – VB series vacuum pumps

Manufacturer PDF

ANVER VB9HV-S regenerative vacuum station

ANVER offers select models of high efficiency vacuum pumps specially designed for ANVER, and used as part of its vacuum lifting systems. These revolutionary regenerative pumps offer a compact, reliable source of quiet, vibration-free vacuum. ANVER’s quality vacuum pumps are made from tough, high-strength materials for long life, and are lightweight and virtually maintenance free. Their highly efficient, state-of-the-art design has rendered the older designs of conventional side-channel blowers obsolete. Vacuum pumps are available in capacities of up to 480+ cfm flow and 18 in. Hg vacuum. Powered by high quality motors, they are more energy efficient, require less horsepower to operate than competitive models, and are offered in a variety of sizes to match your vacuum lifting requirements. NOTE: Optional vacuum or pressure relief valves are also recommended.

All vacuum pump models have rated noise levels of 70–77dB. Optional sound enclosures, specifically designed for each pump model, are available and further reduce the noise level by 5–7dB.

Voltage AvailablePhaseCycle
Dual Voltage: 230/460 or 220/440
Single Voltage: 575V
3 phase60
Single Voltage: 208/380V3 phase50

* Note: When operated at 50 Hz, pump capacity is decreased by 1/6th (16.7%). Consult Factory for more information and other available non-standard configurations.

Performance chart of ANVER high flow pumpsPerformance chart of ANVER high vacuum pumps
High Flow Pumps are especially suitable for porous load applications. They produce air flows up to 350 SCFM making them a natural choice for lifting porous and semi-porous loads. The two pump models available with varying capacities are listed in the High Flow Pump Specifications table below.High-Vacuum Pumps produce vacuum up to 18 in. Hg, which makes them an ideal choice to lift heavy, non-porous to semi-porous loads. The two pump models available with varying capacities are listed in the High Vacuum Pump Specifications table below.

Note:

  • Performance tolerance is +/- 10%.
  • Performance curves are based on 60Hz power supply, air temperature of 60°F (15°C) at the inlet connection, and barometric pressure of 29.92 in. Hg absolute (1013 mbar) at the discharge connection.

Special Orders:

  • Washdown (WAS): Stainless steel fittings
  • Explosion proof models; consult Anver for availability.

Standard regenerative direct-drive vacuum pumps and vacuum stations

Part numbering system for ANVER VB series vacuum stationsDimensional drawing of ANVER VB series regenerative vacuum pump

Notes: *Refer to the pump specification label for actual ratings. Data listed in the table below is subject to change. Before using the pump, confirm that your operating requirements are compatible with the data on the pump specification label.

Specifications
Model No.VB4HF-SVB7HV-SVB8HF-SVB9HV-SVB11HV-S
(Special Order)
A [in. (mm)]28.6 (727)25 (635)30 (762)26 (660)35.3 (897)
B [in. (mm)]15.3 (387)15.3 (387)17.5 (445)17.5 (445)20.5 (521)
C [in. (mm)]15.4 (391)15.8 (400)18.1 (460)18.1 (460)18.1 (460)
D [in. (mm)]5.5 (140)5.8 (146)6 (152)6 (152)6 (152)
E [in. (mm)]11.4 (290)12.9 (328)14.7 (372)14.7 (372)14.6 (371)
Pump Weight [lbs (kg)]75 (34)88 (43)143 (65)129 (51)190 (86)
Power @ 50Hz / 60Hz [HP (Kw)]4.6 (3)3.4 (3)8.4 (6)6.2 (4.6) / 7.1 (5.3)8.9 (6.6)
Flow [SCFM (m3/hr)]220 (370)88 (147)350 (594)120 (203)180 (306)
Maximum Vacuum [in. Hg (mbar)]12 (406)18 (609)12 (406)18 (609)18 (610)
**Recommended “Working” Vacuum Level [In.Hg. (mbar)]10 (339)15 (508)10 (339)15 (508)15 (508)
Maximum Temp [°F (°C)]122 (50)180 (82)142 (61)180 (82)180 (82)
Sound [dB]7670757276
Amps @ 230/460, 220/440 VAC* (60Hz)12.6/7.310.3/6.023.0/13.316.3/9.520.8/12.0
Amps @ 208/380 VAC* (50Hz)12.5/7.29.7/5.623.0/13.315.8/9.1n/a
Amps @ 575 VAC* (60Hz)5.84.687.6n/a
Pump Part NumberVB4HFVB7HVVB8HFVB9HVVB11HV
Muffler Part NumberMU-VB2MU-VB112MU-VB2MU-VB112T.B.D.
Optional Sound Deadening EnclosureSDE-4SDE-7SDE-8SDE-9T.B.D.
Recommended Vacuum Relief Valve KitVRV-112-KIT-4VRV-112-KIT-7/9 or
VRV-112-KIT-7-SDE
VRV-2-KIT-8/11 or
VRV-2-KIT-8-SDE
VRV-112-KIT-7/9 or
VRV-112-KIT-9-SDE
T.B.D.

** ANVER strongly recommends these Maximum Working Vacuum Level settings in order to allow enough free air flow to avoid internal heat build-up.
Excessive thermal expansion of the impeller/chamber will cause interference and friction, resulting in premature wear, internal pump damage, or seizure.

Parts Available for Automation
Product PhotoPart NumberDescription
ANVER 2BX9328 pressure/vacuum changeover valve2BX9328
(Special Order Only)

Valve, Pressure/Vacuum Shuttle for VB4HF Pump (24VDC)

  • Allows you to switch from Vacuum to Pressure Operation.
ANVER 2BX9328 pressure/vacuum changeover valve2BX9328R
(Special Order Only)

Valve, Pressure/Vacuum Shuttle for VB4HF Pump (120VDC Coil with Rectifier)

  • Allows you to switch from Vacuum to Pressure Operation.

Direct-drive vacuum pumps and vacuum stations: vacuum pumps with motors for harsh environments

Regenerative vacuum stations

Note: Vacuum Stations include a large muffler and connection fittings

Station Part Number

HP

Class1/
Division1/
Group D

Class 1/
Division 1/
Group C&D

Class 2/
Division 1/
Group F&G

VB4HF-S4.8VB4HF-S-X11DVB4HF-S-X11CDVB4HF-S-X21FG
VB7HV-S5.0VB7HV-S-X11DVB7HV-S-X11CDVB7HV-S-X21FG
VB8HF-S8.5VB8HF-S-X11DVB8HF-S-X11CDVB8HF-S-X21FG
VB9HV-S7.5VB9HV-S-X11DVB9HV-S-X11CDVB9HV-S-X21FG
VB11HV-S8.9VB11HV-S-X11DVB11HV-S-X11CDVB11HV-S-X21FG

Regenerative vacuum pumps only

Pump Part Number

HP

Class 1/
Division 1/
Group D

Class 1/
Division 1/
Group C&D

Class 2/
Division 1/
Group F&G

VB4HF4.8VB4HF-X11DVB4HF-X11CDVB4HF-X21FG
VB7HV5.0VB7HV-X11DVB7HV-X11CDVB7HV-X21FG
VB8HF8.5VB8HF-X11DVB8HF-X11CDVB8HF-X21FG
VB9HV7.5VB9HV-X11DVB9HV-X11CDVB9HV-X21FG
VB11HV8.9VB11HV-X11DVB11HV-X11CDVB11HV-X21FG

13600081 A

Sound enclosures for vacuum pumps and vacuum stations

Manufacturer PDF

ANVER Vacuum Tube Lifting Systems use vacuum pumps and vacuum stations that already meet OSHA guidelines for noise levels. For added comfort or for use where low noise is desired as a premium, sound deadening enclosures are available in most common sizes. As a general rule, sound enclosures reduce sound by 5-7 dB for vacuum pumps operating in the 68-76 dB range. Although this may seem vague, it is true since sound readings can vary by this amount simply by changing the location where you are standing when you are taking the sound readings. ANVER sound deadening enclosures are built from durable, melt-resistant, industrial-quality plastic. They have a steel plate base and are fully lined with sound deadening foam. It is best to obtain these enclosures when you purchase the vacuum station as they require special plumbing: the intake and exhaust pipes need to be lengthened to port correctly.

The following enclosure sizes are available from stock. When sold separately, extra pipe fittings, though a small amount, must be added. Check with the factory for details.

Dimensional drawing of ANVER sound enclosure

ANVER SDE sound enclosure for vacuum stations
ANVER SDE sound enclosure with strap

Product Photo

Model No.Fits Vacuum StationComplete Station Part Number

A
in.
(mm)

B
in.
(mm)

C
in.
(mm)

Distance Between Mounting Holes
D
in.
(mm)
E
in.
(mm)
ANVER SDE sound enclosureSDE-3ANVER VB3HF-S vacuum station

VB3HF-S

33.00
(838)

24.00
(610)

21.50
(545)

N/AN/A
ANVER SDE sound enclosureSDE-4ANVER VB4HF-S vacuum station

VB4HF-S

33.00
(838)

24.00
(610)

21.50
(545)

35.00
(889)
11.40
(290)
ANVER SDE sound enclosureSDE-41ANVER VB41HF-FR-S vacuum station

VB41HF-FR-S

33.00
(838)

24.00
(610)

21.50
(545)

35.00
(889)
12.75
(324)
ANVER SDE sound enclosureSDE-7ANVER VB7HV-S vacuum station

VB7HV-S

33.00
(838)

24.00
(610)

21.50
(545)

35.00
(889)
12.92
(328)
ANVER SDE sound enclosureSDE-8ANVER VB8HF-S vacuum station

VB8HF-S

29.25
(743)

30.00
(762)

38.75
(984)

31.25
(794)
19.00
(483)
ANVER SDE sound enclosureSDE-9ANVER VB9HV-S vacuum station

VB9HV-S

33.00
(838)

24.00
(610)

21.50
(545)

35.00
(889)
14.64
(372)

13600082 A

Vacuum system accessories: heavy-duty quality exhaust mufflers

MU-VB112 muffler installed on a VB-9 vacuum pump

These attractive, quality exhaust mufflers feature a rugged, heavy-duty construction. The top and bottom covers are cast aluminum with a metal perforated housing for heat resistance. The tie rods and nuts are zinc-plated steel. At an in-line pressure of 90 psi, these mufflers reduce the noise level by 17-22 decibels with little impairment of operating efficiency. They are supplied with NPT male connections .

Specifications

Maximum Pressure: 125 psi

Maximum Temperature: 300°F (149°C)

Product Photo

Part No.

Thread NPT

Description

ANVER exhaust muffler for regenerative vacuum pumps

MU-VB112

1-1/2″

Exhaust Muffler for Regenerative Vacuum Pumps

ANVER exhaust muffler for regenerative vacuum pumps

MU-VB2

2″

Exhaust Muffler for Regenerative Vacuum Pumps

Need an ANVER system for your load?

Send photos, weight and dimensions of the load. FullSharp represents ANVER and replies with a configuration and quote within 24 hours.

Contact us