VPEHE SERIES ELECTRIC VAC-PACK VACUUM STATIONS

ANVER VPEHE electric Vac-Pack vacuum stations: 24, 50 and 78 SCFM, up to 26.5 in. Hg, 1″ NPT. Optional 30 gallon reservoir. 380V/3Ph/50Hz models available.

Description

VPEHE SERIES ELECTRIC VAC-PACK VACUUM STATIONS

VPEHE24 · VPEHE48 · VPEHE75 – self-contained high-flow stations with energy saver circuitry, 24 to 78 SCFM

Product Overview

ANVER VPEHE48-30G-436 electric Vac-Pack vacuum station with 30 gallon reservoir

VPEHE48-30G-436 shown with pendant controls

Self-contained vacuum stations built around high-flow vacuum pumps and energy saver circuitry – suited to custom jigs, special lifters, hold-down clamping, and anywhere a large capacity vacuum source is required.

The VPEHE Vac-Packs handle non-porous through to porous loads and are designed to work with a wide range of lifter assemblies. They are built for heavy production use and can be supplied for heavy duty frames or as stand-alone vacuum stations.

Three sizes cover the range: VPEHE24 (1.5 HP, 24 SCFM), VPEHE48 (3 HP, 50 SCFM) and VPEHE75 (5 HP, 78 SCFM). Each is available in a wide choice of supply voltages, and with or without a 30 gallon vacuum reservoir (the -30G models).

50 Hz supply reduces flow on the larger models – the VPEHE48 delivers 50 SCFM at 60 Hz but 41 SCFM at 50 Hz, and the VPEHE75 78 SCFM at 60 Hz against 65 SCFM at 50 Hz. On a 50 Hz mains, size the station on the 50 Hz figure, not the headline number.

Choosing the Size

VPEHE24

  • Pump 1.5 HP [1.1 kW]
  • Flow 24 SCFM [680 l/min]
  • Maximum vacuum 26.5 in. Hg [673 mm Hg] – the highest of the three
  • Weight 233 lb [106 kg], or 518 lb [235 kg] with reservoir
  • The only size offered on single-phase supplies

VPEHE48

  • Pump 3 HP [2.2 kW]
  • Flow 50 SCFM [1,426 l/min] at 60 Hz, 41 SCFM [1,161 l/min] at 50 Hz
  • Maximum vacuum 25 in. Hg [635 mm Hg]
  • Weight 370 lb [168 kg], or 611 lb [277 kg] with reservoir
  • Three-phase only

VPEHE75

  • Pump 5 HP [3.7 kW]
  • Flow 78 SCFM [2,209 l/min] at 60 Hz, 65 SCFM [1,841 l/min] at 50 Hz
  • Maximum vacuum 25 in. Hg [635 mm Hg]
  • Weight 454 lb [206 kg], or 739 lb [335 kg] with reservoir
  • Three-phase only

All three sizes share a 1″ NPT vacuum port. Flow decides how quickly a leaking or porous load is held; maximum vacuum decides the holding force per unit of pad area.

Safety Features

Vacuum Control

A solid-state control unit combines every vacuum generator control in one rugged package – all pump functions, the safety lights, and the standard audible vacuum leakage warning system.

Audible leakage warning

An electronically controlled vacuum loss sensor monitors the level and sounds an alarm if a slow leak brings the vacuum down to a pre-set point.

Vacuum retention

An internal check valve stops loss of vacuum if power fails (non-porous loads). A 30 gallon [6,939 cu. in.] reservoir is fitted on -30G models to help hold a safe level through a power failure.

Reservoir or not? – the reservoir is what buys time to set a load down after a power failure or a slow leak, so specify a -30G model for any overhead lifting duty. It adds roughly 240 to 285 lb [110 to 130 kg] to the station, which is why the plain models exist for jigs, fixtures and hold-down clamping where the load is not suspended.

Additional Features and Maintenance

Front control panel and gauges

All gauges, lights and power switches are mounted on the front of the control panel. Two vacuum gauges show the level in the manifold and in the reservoir separately.

Indicator lights

Front enclosure plus left and right auxiliary: green = safe vacuum level, red = unsafe vacuum level, white = power on.

Electrical enclosure door

Every generator has a hinged electrical enclosure door for direct access to the electrical components.

Moisture trap / air filters

Two over-sized screw-on clear filter bowls, mounted outside the electrical enclosure so they can be inspected and cleaned without opening it.

Vacuum pump – PMPHE Series

All pumps are oil-less rotary vane type with thermally overload protected motors. No oil change routine and no oil carry-over into the vacuum line.

Forklift transport

These are floor-standing stations from 233 to 739 lb [106 to 335 kg] – they are moved and positioned with an ordinary forklift.

Specifications

VPEHE24 Series vacuum stations

VPEHE24 electric vacuum station dimensional drawing

VPEHE24 – standard

VPEHE24-30G electric vacuum station with 30 gallon reservoir dimensional drawing

VPEHE24-30G – with reservoir

VPEHE24 – 1.5 HP [1.1 kW] · 26.5 in. Hg [673 mm Hg] · 24 SCFM [680 l/min] · 1″ NPT
Model no. Incoming power Incoming amperage Vacuum pump [HP (kW)] Maximum vacuum [in. Hg (mm Hg)] Flow [SCFM (l/min)] Port [NPT] Weight [lb (kg)]
Standard – 60 Hz
VPEHE24-116 110 V / 1 PH / 60 Hz 23 1.5 (1.1) 26.5 (673) 24 (680) 1″ 233 (106)
VPEHE24-216 220 V / 1 PH / 60 Hz 11.5 1.5 (1.1) 26.5 (673) 24 (680) 1″ 233 (106)
VPEHE24-236 230 V / 3 PH / 60 Hz 14 1.5 (1.1) 26.5 (673) 24 (680) 1″ 233 (106)
VPEHE24-436 460 V / 3 PH / 60 Hz 7 1.5 (1.1) 26.5 (673) 24 (680) 1″ 233 (106)
VPEHE24-536 575 V / 3 PH / 60 Hz TBD 1.5 (1.1) 26.5 (673) 24 (680) 1″ 233 (106)
Standard – 50 Hz
VPEHE24-115 110 V / 1 PH / 50 Hz TBD 1.5 (1.1) 26.5 (673) 24 (680) 1″ 233 (106)
VPEHE24-215 220 V / 1 PH / 50 Hz TBD 1.5 (1.1) 26.5 (673) 24 (680) 1″ 233 (106)
VPEHE24-235 220 V / 3 PH / 50 Hz TBD 1.5 (1.1) 26.5 (673) 24 (680) 1″ 233 (106)
VPEHE24-335 380 V / 3 PH / 50 Hz TBD 1.5 (1.1) 26.5 (673) 24 (680) 1″ 233 (106)
VPEHE24-435 440 V / 3 PH / 50 Hz TBD 1.5 (1.1) 26.5 (673) 24 (680) 1″ 233 (106)
With 30 gallon reservoir (-30G) – 60 Hz
VPEHE24-30G-116 110 V / 1 PH / 60 Hz 23 1.5 (1.1) 26.5 (673) 24 (680) 1″ 518 (235)
VPEHE24-30G-216 220 V / 1 PH / 60 Hz 11.5 1.5 (1.1) 26.5 (673) 24 (680) 1″ 518 (235)
VPEHE24-30G-236 230 V / 3 PH / 60 Hz 14 1.5 (1.1) 26.5 (673) 24 (680) 1″ 518 (235)
VPEHE24-30G-436 460 V / 3 PH / 60 Hz 7 1.5 (1.1) 26.5 (673) 24 (680) 1″ 518 (235)
VPEHE24-30G-536 575 V / 3 PH / 60 Hz TBD 1.5 (1.1) 26.5 (673) 24 (680) 1″ 518 (235)
With 30 gallon reservoir (-30G) – 50 Hz
VPEHE24-30G-115 110 V / 1 PH / 50 Hz TBD 1.5 (1.1) 26.5 (673) 24 (680) 1″ 518 (235)
VPEHE24-30G-215 220 V / 1 PH / 50 Hz TBD 1.5 (1.1) 26.5 (673) 24 (680) 1″ 518 (235)
VPEHE24-30G-235 220 V / 3 PH / 50 Hz TBD 1.5 (1.1) 26.5 (673) 24 (680) 1″ 518 (235)
VPEHE24-30G-335 380 V / 3 PH / 50 Hz TBD 1.5 (1.1) 26.5 (673) 24 (680) 1″ 518 (235)
VPEHE24-30G-435 440 V / 3 PH / 50 Hz TBD 1.5 (1.1) 26.5 (673) 24 (680) 1″ 518 (235)

Reference document 13600094 C.

VPEHE48 Series vacuum stations

VPEHE48 electric vacuum station dimensional drawing

VPEHE48 – standard

VPEHE48-30G electric vacuum station with 30 gallon reservoir dimensional drawing

VPEHE48-30G – with reservoir

VPEHE48 – 3 HP [2.2 kW] · 25 in. Hg [635 mm Hg] · 1″ NPT
Model no. Incoming power Incoming amperage Vacuum pump [HP (kW)] Maximum vacuum [in. Hg (mm Hg)] Flow [SCFM (l/min)] Port [NPT] Weight [lb (kg)]
Standard – 60 Hz
VPEHE48-236 230 V / 3 PH / 60 Hz 12 3 (2.2) 25 (635) 50 (1426) 1″ 370 (168)
VPEHE48-436 460 V / 3 PH / 60 Hz 6 3 (2.2) 25 (635) 50 (1426) 1″ 370 (168)
VPEHE48-536 575 V / 3 PH / 60 Hz TBD 3 (2.2) 25 (635) 50 (1426) 1″ 370 (168)
Standard – 50 Hz
VPEHE48-235 220 V / 3 PH / 50 Hz TBD 3 (2.2) 25 (635) 41 (1161) 1″ 370 (168)
VPEHE48-335 380 V / 3 PH / 50 Hz TBD 3 (2.2) 25 (635) 41 (1161) 1″ 370 (168)
VPEHE48-435 440 V / 3 PH / 50 Hz TBD 3 (2.2) 25 (635) 41 (1161) 1″ 370 (168)
With 30 gallon reservoir (-30G) – 60 Hz
VPEHE48-30G-236 230 V / 3 PH / 60 Hz 12 3 (2.2) 25 (635) 50 (1426) 1″ 611 (277)
VPEHE48-30G-436 460 V / 3 PH / 60 Hz 6 3 (2.2) 25 (635) 50 (1426) 1″ 611 (277)
VPEHE48-30G-536 575 V / 3 PH / 60 Hz TBD 3 (2.2) 25 (635) 50 (1426) 1″ 611 (277)
With 30 gallon reservoir (-30G) – 50 Hz
VPEHE48-30G-235 220 V / 3 PH / 50 Hz TBD 3 (2.2) 25 (635) 41 (1161) 1″ 611 (277)
VPEHE48-30G-335 380 V / 3 PH / 50 Hz TBD 3 (2.2) 25 (635) 41 (1161) 1″ 611 (277)
VPEHE48-30G-435 440 V / 3 PH / 50 Hz TBD 3 (2.2) 25 (635) 41 (1161) 1″ 611 (277)

Reference document 13600095 C.

VPEHE75 Series vacuum stations

VPEHE75 electric vacuum station dimensional drawing

VPEHE75 – standard

VPEHE75-30G electric vacuum station with 30 gallon reservoir dimensional drawing

VPEHE75-30G – with reservoir

VPEHE75 – 5 HP [3.7 kW] · 25 in. Hg [635 mm Hg] · 1″ NPT
Model no. Incoming power Incoming amperage Vacuum pump [HP (kW)] Maximum vacuum [in. Hg (mm Hg)] Flow [SCFM (l/min)] Port [NPT] Weight [lb (kg)]
Standard – 60 Hz
VPEHE75-236 230 V / 3 PH / 60 Hz 19 5 (3.7) 25 (635) 78 (2209) 1″ 454 (206)
VPEHE75-436 460 V / 3 PH / 60 Hz 10 5 (3.7) 25 (635) 78 (2209) 1″ 454 (206)
VPEHE75-536 575 V / 3 PH / 60 Hz TBD 5 (3.7) 25 (635) 78 (2209) 1″ 454 (206)
Standard – 50 Hz
VPEHE75-235 220 V / 3 PH / 50 Hz TBD 5 (3.7) 25 (635) 65 (1841) 1″ 454 (206)
VPEHE75-335 380 V / 3 PH / 50 Hz 18 5 (3.7) 25 (635) 65 (1841) 1″ 454 (206)
VPEHE75-435 440 V / 3 PH / 50 Hz 12 5 (3.7) 25 (635) 65 (1841) 1″ 454 (206)
With 30 gallon reservoir (-30G) – 60 Hz
VPEHE75-30G-236 230 V / 3 PH / 60 Hz 19 5 (3.7) 25 (635) 78 (2209) 1″ 739 (335)
VPEHE75-30G-436 460 V / 3 PH / 60 Hz 10 5 (3.7) 25 (635) 78 (2209) 1″ 739 (335)
VPEHE75-30G-536 575 V / 3 PH / 60 Hz TBD 5 (3.7) 25 (635) 78 (2209) 1″ 739 (335)
With 30 gallon reservoir (-30G) – 50 Hz
VPEHE75-30G-235 220 V / 3 PH / 50 Hz TBD 5 (3.7) 25 (635) 65 (1841) 1″ 739 (335)
VPEHE75-30G-335 380 V / 3 PH / 50 Hz 18 5 (3.7) 25 (635) 65 (1841) 1″ 739 (335)
VPEHE75-30G-435 440 V / 3 PH / 50 Hz 12 5 (3.7) 25 (635) 65 (1841) 1″ 739 (335)

Reference document 13600096 E.

Supply Voltages Available

The last three digits of the model number are the wiring code. Use this table to read off the correct model for the site supply.

Model number by available wiring (V / Ph / Hz)
Supply VPEHE24 VPEHE48 VPEHE75
60 Hz
115 V / 1 Ph / 60 Hz VPEHE24-116 N/A N/A
230 V / 1 Ph / 60 Hz VPEHE24-216 N/A N/A
230 V / 3 Ph / 60 Hz VPEHE24-236 VPEHE48-236 VPEHE75-236
460 V / 3 Ph / 60 Hz VPEHE24-436 VPEHE48-436 VPEHE75-436
575 V / 3 Ph / 60 Hz VPEHE24-536 VPEHE48-536 VPEHE75-536
50 Hz
110 V / 1 Ph / 50 Hz VPEHE24-115 N/A N/A
220 V / 1 Ph / 50 Hz VPEHE24-215 N/A N/A
220 V / 3 Ph / 50 Hz VPEHE24-235 VPEHE48-235 VPEHE75-235
380 V / 3 Ph / 50 Hz VPEHE24-335 VPEHE48-335 VPEHE75-335
440 V / 3 Ph / 50 Hz VPEHE24-435 VPEHE48-435 VPEHE75-435
575 V / 3 Ph / 50 Hz N/A N/A N/A

For a 380 V / 3 Ph / 50 Hz site supply the models are VPEHE24-335, VPEHE48-335 and VPEHE75-335 – add -30G before the wiring code for the reservoir version, e.g. VPEHE48-30G-335.

Larger Vac-Packs and complete vacuum stations are available for specialised applications – contact FULL-SHARP for details.

Operator Controls

Three control styles are offered. All three cover attach, release and safety interlock.

Product photo Part number Description
ANVER RCPK-AC/DC-ARI radio control kit for Vac-Packs RCPK-AC/DC-ARI Radio control kit – attach / release / interlock. Hand-held three-button transmitter; the holster mounts on the front handlebar and the plug-in receiver mounts on the side of the vacuum generator.
Includes: radio control transmitter and mounting holster; radio control receiver and mounting bracket.
ANVER EPK-AC/DC-ARI plug-in pendant control kit for Vac-Packs EPK-AC/DC-ARI Pendant control kit – attach / release / interlock. Momentary attach/release switch and safety interlock push-button on the pendant.
Includes: pendant control and mounting holster; plug-in replaceable coil cord, 10 ft long.
ANVER plug-in control harness for customer supplied radio receiver Contact factory Plug-in harness – customer radio receiver interface. Lets the customer wire their own radio receiver for attach / release / interlock, so an existing plant radio system can drive the Vac-Pack.
Includes: cord, 3 ft long.

Radio control suits an operator who needs to walk clear of the load; the pendant is the simpler option where the operator stays at the lifter; the harness is for integrating an existing radio system.

Installation and Transport

These are floor-standing stations, so they are positioned with a forklift whether they are being mounted on a heavy duty lifting frame or set up as a stand-alone source.

Before ordering, confirm three things: the site supply voltage, phase and frequency; whether the duty needs the 30 gallon reservoir; and the flow required by the load – a porous or leaking material sets the pump size, not the weight being lifted.

ANVER VPEHE48 electric vacuum station being transported by forklift

VPEHE48 moved by forklift

Reviews

There are no reviews yet.

Be the first to review “VPEHE SERIES ELECTRIC VAC-PACK VACUUM STATIONS”

Your email address will not be published. Required fields are marked *