MOTOR STARTERS AND PROTECTORS

ANVER motor starters combine short circuit protection, overload protection and switching in one unit — 0.1 to 25 FLA, with enclosure. Transformers also listed.

Description

MOTOR STARTERS AND PROTECTORS

Electric vacuum pump station accessories – short circuit protection, current overload protection and switching in one unit

Product Overview

ANVER motor starter for vacuum pumps

ANVER motor starter

ANVER motor starters are made to the highest quality standards. The motor circuit controller combines the function of short circuit protection, current overload protection and switching. Three phase.

ANVER starters can eliminate the need for larger and more expensive fuse blocks and fused disconnects, or circuit breakers. They offer a wide application range, from 0.1 to 25 Full Load Amp (FLA). For group motor applications, ANVER starters have a group installation rating of up to 600 V @ 2,000 Amp, one of the highest in the industry.

ANVER starters are also excellent as manual motor starters that employ all of the same motor protection features in one compact unit – the most compact on the market today. In the event of a short-circuit, the contacts are opened by non-adjusting tripping elements in times approaching 1/1000 of a second.

Because each ANVER starter is individually calibrated at the factory for the smallest and largest current, very accurate thermal overload protection is also obtained.

Each motor starter now comes with an enclosure.

Motor Starter Specifications

Horsepower ratings shown below are for reference. The final selection of the manual starter depends on the actual motor full load current and service factor.

ANVER motor starter dimensions and ratings

ANVER motor starters
ANVER part no. Amperage range – minimum Amperage range – maximum Phase Item weight [lb (kg)] Maximum HP – 230 V Maximum HP – 460 V Maximum HP – 575 V
ST-025-040 2.50 4.00 Three N/A 3/4 2 3
ST-040-063 4.00 6.29 Three 1.66 (0.75) 3 5
ST-063-100 6.30 9.99 Three N/A 3 5
ST-100-160 10.00 15.99 Three 1.66 (0.75) 5 10 10

Appropriate Motor Starters for ANVER Vacuum Pumps

ANVER vacuum pump and motor starter selection

Appropriate motor starters for ANVER vacuum pumps
ANVER pump no. HP Recommended starter no. Voltage Amps Port size Hose [in. (mm)]
ANVER VB4HF vacuum pumpVB4HF 4.6 HP ST-100-160 208-230 12.6 2″ NPT 2 (50.8)
ST-063-100 460 7.3
ST-040-063 575 5
ANVER VB7HV vacuum pumpVB7HV 4.8 HP ST-100-160 208-230 10.3 1-1/4″ NPT 2 (50.8)
ST-063-100 460 5.0
ST-025-040 575 3.9
ANVER VB8HF vacuum pumpVB8HF 8.5 HP ST-200-250 208-230 24 2″ NPT 2 (50.8)
ST-100-160 460 12
ST-100-160 575 8.5
ANVER VB9HV vacuum pumpVB9HV 7.5 HP ST-160-200 208-230 16.4 1-1/4″ NPT 2 (50.8)
ST-063-100 460 9.5
ST-040-063 575 5.4

Electrical Transformers for Vacuum Generators

ANVER VLT Series electrical transformer for vacuum generators

Electrical transformers for vacuum generators
Model number Unit weight Used with generator Incoming primary voltage Outgoing secondary voltage Wattage A depth [in. (mm)] B width [in. (mm)] C height [in. (mm)] D top holes [in. (mm)] E bottom holes [in. (mm)] F holes distance, top to bottom [in. (mm)] Item weight [lb (kg)]
VLT-01 30 lb (14 kg) VPE1, VPF-57 240 V, 480 V 60 Hz 120 V 60 Hz 1.5 KVA 5.2 (132) 5.5 (140) 10.3 (262) 1.4 (36) 2.4 (61) 11.6 (295) N/A
VLT-03 38 lb (17 kg) VPE3 240 V, 480 V 60 Hz 120 V 60 Hz 2 KVA 4.5 (114) 4.8 (122) 11.8 (300) 1.4 (36) 2.1 (53) 13.0 (330) N/A
VLT-06 30 lb (14 kg) VPE1, VPF-57 600 V 60 Hz 120 V 60 Hz 1.5 KVA 5.2 (132) 5.5 (140) 10.3 (262) 1.4 (36) 2.4 (61) 11.6 (295) N/A
VLT-14 (export model) 38 lb (17 kg) VPE1, VPF-57, VPE3 190 V, 200 V, 208 V, 380 V, 400 V, 416 V 50/60 Hz 120 V 50/60 Hz 2 KVA 5.2 (132) 5.5 (140) 13 (330) 1.4 (36) 2.1 (53) 13.5 (343) 3.81 (1.73)

Transformers should be remote mounted. Increasingly, many local regulations require that three phase power is not run below the hook. This is usually the case with smaller units intended to be used by an operator, so the transformer should be wall or remotely mounted for safety. FULL-SHARP supplies the proper transformers for these lifters; they ship separately in a box and need to be installed by a qualified electrician. It is usually best to contract this to a local crane installer or electrician familiar with local code requirements.

Other voltages / phases available – generators can be supplied in 208 V, 220 V, 230 V, 380 V, 440 V, 460 V, 480 V and 575 V by adding a transformer (consult the factory for more information). All generator motors with a voltage of 120 V or less use fuses or circuit breakers for protection. Motors and other devices using more than 200 V are fused and / or use thermal overload with a contactor.

Standards and Compliance

All ANVER electrical components, controls and wiring follow international standards: UL, CSA, NFPA, NEC. It is the user’s responsibility to comply with all additional local electrical codes as they pertain to the installation.

ASME B30.20 – power disconnects. The standard requires that hoisting equipment using an externally powered vacuum lifter has a separate vacuum lifter circuit switch of the enclosed type, with provision for locking, flagging or tagging in the open (off) position. That disconnect switch must be connected on the line side – the power supply side – of the hoisting equipment disconnect switch. Disconnects are not required on externally powered vacuum lifters operating from a 120 VAC single phase power source.